{"id":1478,"date":"2023-01-10T05:42:35","date_gmt":"2023-01-10T05:42:35","guid":{"rendered":"https:\/\/beamq.com\/laser\/?p=1478"},"modified":"2023-01-10T05:42:35","modified_gmt":"2023-01-10T05:42:35","slug":"337-1-nm-337nm-uv-laser-compact-nitrogen-laser-mnl-300","status":"publish","type":"post","link":"https:\/\/beamq.com\/laser\/337-1-nm-337nm-uv-laser-compact-nitrogen-laser-mnl-300\/","title":{"rendered":"337.1 nm 337nm UV Laser Compact Nitrogen Laser MNL 300"},"content":{"rendered":"\n<p><a href=\"https:\/\/www.beamq.com\/3371-nm-337nm-uv-laser-compact-nitrogen-laser-mnl-300-p-2522.html\">337.1 nm 337nm UV Laser Compact Nitrogen Laser MNL 300<\/a><\/p>\n\n\n\n<p>The MNL 300 is the ideal light source for applications like fluorescence, phosphorescence and mass spectrometry in research, medical diagnostics and industry.<\/p>\n\n\n\n<p>Wavelength 337.1 nm<br>Long operating life<br>For low-cost applications<br>Compact design<br>Certifications: CE, ETL-Report No. 2212292WIE-004 (Intertek: UL, CSA), ROHS, FDA<br>Compatible with VSL337i OEM<\/p>\n\n\n\n<p>SETUP<\/p>\n\n\n\n<p>Compact, reliable and cost-efficient, the Mini Nitrogen Laser MNL 300 can provide pulse energies up to 85 \u00b5J and repetition rates up to 80 Hz with a maximum average power of 5 mW. It is characterized by its long lifetime, low energy decay and high precision. This is achieved by the patented innovations:<\/p>\n\n\n\n<p>\u2022 Sealed cartridge in metal-ceramics technology<br>\u2022 Directly switching solid state power switch<\/p>\n\n\n\n<p>The MNL 300 presents the advantages of modern laser technology. Only an external trigger signal is required for its operation. That is the reason why its use is so simple. The standard version with free beam can be equipped with an optical fiber for the light output allowing the best integration into the customers\u2018 applications. Moreover it is possible to couple the MNL 300 with a tuning module in order to provide several wavelengths of the whole visible spectrum.<\/p>\n\n\n\n<p>The air-cooled MNL 300 is supplied with a low voltage of 24 V DC \/ 60W. A wide range power supply (100 \u2013 240 V, 50 \u2013 60 Hz) can be obtained from LTB, if required. Small, compact, with a total volume of 2.2 litres, the MNL 300 will provide you the best performance of a UV-laser in this price segment.<\/p>\n\n\n\n<p>Options:<\/p>\n\n\n\n<p>\u2022 Fiber coupling and fibers<br>\u2022 Dye laser module<\/p>\n\n\n\n<p>Wavelength nm 337.1<br>Spectral bandwidth nm 0.1<br>Pulse halfwidth FWHM, typ. ns 3<br>Guaranteed pulse energy over 60 million pulses \u00b5J 85@20Hz \/ 80@50Hz \/ 75@80Hz<br>Pulse power, typ. kW 28@20Hz \/ 26@50Hz \/ 25@80Hz<br>Repetition rate Hz 1\u202680<br>Energy stability SD % \u2264 2<br>Beam dimensions, vertical x horizontal, typ. mm 3 x 4<br>Beam divergence, vertical x horizontal mrad \u2264 3.5 x \u2264 3<br>Focus stability \u00b5m &lt; 15<br>Beam exit angle, vertical x horizontal, typ. grad + 0.5 (\u00b1 0,2) x 0\u00b10.1<br>Trigger in optical or electrical (TTL)<br>Jitter: ext. trigger \u2013 laser pulse ns \u00b1 5<br>Pulse delay: ext. trigger \u2013 laser pulse ns 1,600 \u00b1 10%<br>Sync Out (optional)<br>Jitter: electr. trigger exit \u2013 laser pulse ns &lt; 0.2<br>Warm-up time s &lt; 20<br>Control automode or software (DLL) via integrated controller<br>Warranty 40 (60) million pulses or 2 (3) years<br>Certifications CE, ETL (ANSI\/UL 61010-1, CAN\/CSA C22.2#61010-1), FDA 1<br>Laser class 3B \/ IIIb<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-file\"><a href=\"https:\/\/beamq.com\/laser\/wp-content\/uploads\/2023\/01\/337.1-nm-337nm-UV-Laser-mnl300-datasheet.pdf\">337.1-nm-337nm-UV-Laser-mnl300-datasheet<\/a><a href=\"https:\/\/beamq.com\/laser\/wp-content\/uploads\/2023\/01\/337.1-nm-337nm-UV-Laser-mnl300-datasheet.pdf\" class=\"wp-block-file__button\" download>Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>337.1 nm 337nm UV Laser Compact Nitrogen Laser MNL 300 The MNL 300 is the ideal light source for applications like fluorescence, phosphorescence and mass spectrometry in research, medical diagnostics and industry. Wavelength 337.1 nmLong operating lifeFor low-cost applicationsCompact designCertifications: CE, ETL-Report No. 2212292WIE-004 (Intertek: UL, CSA), ROHS, FDACompatible with VSL337i OEM SETUP Compact, reliable [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1479,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/posts\/1478"}],"collection":[{"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/comments?post=1478"}],"version-history":[{"count":1,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/posts\/1478\/revisions"}],"predecessor-version":[{"id":1481,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/posts\/1478\/revisions\/1481"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/media\/1479"}],"wp:attachment":[{"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/media?parent=1478"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/categories?post=1478"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/beamq.com\/laser\/wp-json\/wp\/v2\/tags?post=1478"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}